<LOGO>
FM Transmitter Measurement Report
Created: 2026-03-04 04-57-21
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 43 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 1.9 kHz 72 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 61 kHz 14880 0,0470
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,3 dBr 4,16 dBr 5,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 4:57, 4.03.2026
RT
"YleX Aamu: Päivän parhaat "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 61 kHz MIN: 12 kHz % above 76 kHz: 0,0470 Acquired: 2026/03/04 4.56.17 Total samples: 14880 Equivalent time: 0:12:24 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,0 dBr MIN: 2,3 dBr AVE: 4,16 dBr % above 12,2 dBr: 0,0 Last value: 3,8 dBr (2026/03/04 4.56.17) 04.42 04.44 04.46 04.48 04.50 04.52 04.54 04.56 0 2 4 6 Pm [dBr]